Heat across the floor
The mineral floor supports heat transfer from the underfloor heating. The indoor climate remains a matter of the overall system.
VIA material knowledge · Hamburg projects
Mineral flooring. Warmth from below. VIA terrazzo can be combined with electric and water-based underfloor heating systems—provided the heating system and floor build-up are planned together.
For your new installation or renovation in Hamburg and the surrounding area, SteinWert will discuss the terrazzo specification and the necessary interfaces with the specialist design team. Our business is based in Potsdam; site visits and work in Hamburg are arranged individually.
From Uhlenhorst and Rotherbaum to St. Georg and Altona-Altstadt: technical suitability is assessed for each specific property. Explore Hamburg neighbourhood profiles and project contexts.

Material & warmth
VIA describes terrazzo’s thermal conductivity as a suitable basis for distributing heat from underfloor heating. Actual comfort and energy requirements depend on the building as a whole and its heating design.
The mineral floor supports heat transfer from the underfloor heating. The indoor climate remains a matter of the overall system.
According to VIA, electric and water-based systems are suitable options. Not every product is automatically compatible with every build-up.
From planned new installation to retrofitting: the subfloor and available height determine the right approach.
For water-based systems, the connection to the heat source is also considered—for example, a system with solar thermal energy.
Electric underfloor heating
The two original VIA diagrams show the difference between a standard interior and a wet area. Each diagram can be opened and enlarged separately for a closer look.
In VIA’s application example, the build-up combines a load-bearing screed with primer, tile adhesive, and an insulating and uncoupling layer. The electric heating is installed beneath the finished terrazzo surface. Connections and perimeter details are part of the system design.

The dimensions in this diagram apply exclusively to the VIA system build-up shown. They are not a standard build-up height for every property.
For wet areas, VIA shows an adapted build-up with waterproofing, sealing tape and perimeter details. Moisture protection, the subfloor and the heating must be coordinated together. A build-up for a dry living area cannot be transferred unchanged to a wet area.

The stated layer thicknesses and reference heights apply only to this application example. The current approval and planning are authoritative.
Retrofitting water-based heating
VIA documents the renovation of a 1960s detached house. The heating pipes are milled into the existing screed before the new terrazzo floor is installed. Where the existing structure is suitable, this approach can limit the additional build-up height.
01 / 10The VIA example starts with a 1960s detached house. The old floor covering, screed and available height are assessed before retrofitting.
Image: VIA material
02 / 10After the floor covering is removed, adhesive residue and uneven areas are ground down. Further work requires a suitable substrate.
Image: VIA material
03 / 10Channels for water-based heating can be milled into suitable existing screed. Whether this space-saving solution is possible must be checked in advance.
Image: VIA material
04 / 10The milled channels and the surface are thoroughly vacuumed. Preparing the substrate is part of the coordinated floor build-up.
Image: VIA material
05 / 10The water-based pipes are laid in the channels provided. The heating system and flooring work must be coordinated.
Image: VIA material
06 / 10The pipes are covered with filler in the next step. The materials used must be compatible with the screed, heating system and subsequent floor build-up.
Image: VIA material
07 / 10VIA then shows a decoupling layer, for example PROSECUREfibretec 2.0 by Proline or a suitable comparable system. The choice is made as part of the coordinated floor build-up.
Image: VIA material
08 / 10The terrazzo mix is spread, smoothed and levelled over the clean, primed surface. Direct sunlight and draughts should be avoided during installation.
Image: VIA material
09 / 10Dry grinding reveals the material’s appearance and develops the finished surface. The grinding stages depend on the current VIA grinding guidelines and the project conditions.
Image: VIA material
10 / 10In the example, VIA mineral impregnation is applied to the dry, clean surface with a floor mop, using crosswise strokes. Protection and subsequent care complete the floor build-up.
Image: VIA material
Before planning
The key answers on combining terrazzo, heating and existing floor structures.
VIA describes terrazzo as compatible with electric and water-based underfloor heating. The suitability of the complete floor build-up is decisive. The specific heating system must be agreed with VIA’s technical team before the project begins.
The VIA website shows a renovation example in which water pipes are routed into an existing screed by milling. Whether this solution is suitable for your property depends, among other things, on the condition and construction of the screed and the available floor height. The manufacturer’s example is not a general guarantee that it will work in every existing building.
For wet areas, VIA shows a dedicated floor build-up with waterproofing and coordinated perimeter connections. The substrate, moisture protection, decoupling and heating system must be planned together. The current technical details must be agreed before installation.
There is no universally applicable height. The VIA diagrams give layer dimensions for specific defined systems and take account of material removed during grinding. For each project, the screed, decoupling, waterproofing, heating system and connections must be assessed together.
Send us the property’s location, a floor plan or photos, the approximate area, the existing floor build-up and the available height. Please also say whether electric or water-based underfloor heating is planned or already installed, and whether the area is a wet area. SteinWert will discuss the terrazzo specification and the technical coordination required for Hamburg and the surrounding area.
Hamburg & surrounding area
Send us the area, property location, photos of the substrate and details of the proposed heating system. We will discuss the terrazzo specification and the technical coordination required.
Technical information in our own words, based on the VIA manufacturer’s website, as at 24.10.2026. Photos and floor build-up diagrams: VIA Material; the diagrams credit VIA GmbH as the source. The current technical documents and project-specific coordination with VIA’s technical team take precedence.